ยังไม่มีสื่อแสดงผล
คุณสมบัติและข้อมูลเชิงเทคนิค
Easy-to-clean construction
Standard blowers used by Pharmacon™ DFB are closed loop ECM fans. These are energy-efficient blowers with the ability to automatically adjust fan speed in response to filter loading.
75 dBa is Possible
Noise level of ≤75 dBa can be achieved during factory testing; carried out in free field with clean filters and without sound foam.
Rapid Tool-less Filter Changing
The sampling booth is equipped with knife-edge gel sealed filters capable for a ‘rapid tool-less replacement’ within the booth.
ISO Class 5 Air Quality (at rest)
Esco Pharma DFB can achieve ISO Class 5 air quality (at rest conditions) with its wide array of standard filtration options. Client can specify the type based on their application (dust burden level).
Energy Efficient Lighting
Flush mounted energy efficient LED light fixtures in the booth side walls or ceiling ensures minimal glare and sufficient lighting in the work zone.
Improved Airflow Characteristics
LED lighting design placement ensures improved airflow regime with the minimum distance between the ceiling HEPA filters and diffusers.
Antimicrobial Powder Coating
For powder coated sampling / weighing booths, Esco Pharma utilizes the Isocide™ anti-microbial powder coating on all panels.
Principle
- Air is delivered into the Operator’s Breathing Zone (OBZ) via the overhead HEPA filters, thus providing a clean and safe environment.
- Potential dust clouds are suppressed and removed via the exhaust filtration system.
- The operator carries out tasks in the high velocity zone at the rear of the Booth so that dangerous dusts will not rise into the breathing zone.
- Product protection is assured by customising the downflow booth’s layout to suit the processes being carried out.
- The Booth provides a stand-alone work place that doesn’t require the connection of external ventilation systems.
|
Configurations |
Options |
Model |
||
|
0.3 m Back Stack |
0.6 m Back Stack |
1.0 m Back Stack |
||
|
Series |
Option SC: Safe Change |
NA |
NA |
✔ |
|
Option SCNB: Safe Change No-Bag |
NA |
NA |
✔ |
|
|
Option ST: Standard |
✔ |
✔ |
NA |
|
|
Explosive Rating |
Option SA : Safe Area |
✔ |
✔ |
✔ |
|
Option ED: Explosive Dust |
NA |
✔ |
✔ |
|
|
Option EG: Explosive Gas |
NA |
✔ |
✔ |
|
|
Dimensional Option |
Internal Height Options (m) |
2.1, 2.5 |
2.1, 2.5 |
2.1, 2.5 |
|
External Width Options (m) |
1.6, 1.8, 2.0, 2.4, 2.6, 2.8, |
1.6, 1.8, 2.0, 2.4, 2.6, 2.8, |
1.6, 1.8, 2.0, 2.4, 2.6, 2.8, |
|
|
3.0, 3.2, 3.4, 3.6, 3.8, 4.0, |
3.0, 3.2, 3.4, 3.6, 3.8, 4.0, |
3.0, 3.2, 3.4, 3.6, 3.8, 4.0, |
||
|
4.2, 4.4, 4.6, 4.8, 5.0 |
4.2, 4.4, 4.6, 4.8, 5.0 |
4.2, 4.4, 4.6, 4.8, 5.0 |
||
|
Internal Depth Options (m) |
0.8, 1.2, 1.6 |
0.8, 1.2, 1.6, 2.0, 2.4 |
0.8, 1.2, 1.6, 2.0, 2.4, 2.8 |
|
|
Filter
Arrangement |
Option A - G4,F8,H13,H14,PLF |
NA |
NA |
✔ |
|
Option B - G4,F8,H13,H14 |
NA |
NA |
✔ |
|
|
Option C - G4,F8,H13,PLF |
NA |
NA |
✔ |
|
|
Option D - G4,F8,H14 |
NA |
✔ |
NA |
|
|
Option E - Carbon,H14 |
✔ |
NA |
NA |
|
|
Option F - Front |
✔ |
NA |
NA |
|
|
Fan / Filter Access |
Option A - Internal to Booth |
✔ |
✔ |
✔ |
|
Option B - External Area |
NA |
NA |
✔ |
|
|
Airflow Arrangement |
Option R - Recirculating |
✔ |
✔ |
✔ |
|
Option S - Single Pass |
NA |
NA |
✔ |
|
|
Bleed Position |
Option T - Top |
NA |
NA |
✔ |
|
Option F - Front |
✔ |
✔ |
✔ |
|
|
M.O.C. Options |
Option P: Ceiling Plenum |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
Option Q: Side Panels, Rear Wall |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
|
Option R: Filter Housings, Fan Boxes, Spacer (if present) & Transition |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
|
Option S: Plinth |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
|
Option T: Exhaust Grilles |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
|
Option U: Exterior Side Panels |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
A: SS 316, B: SS 304, |
|
|
PVC Curtains |
Option T - Top |
NA |
NA |
✔ |
|
Option F - Front |
✔ |
✔ |
✔ |
|
|
LOP Location |
Option R - Right Panel |
✔ |
✔ |
✔ |
|
Option L - Left Panel |
✔ |
✔ |
✔ |
|
|
Option F - Front Panel |
✔ |
✔ |
✔ |
|
|
Supply Voltage |
Option A - 220V-240V 50 Hz 1Ph |
✔ |
NA |
NA |
|
Option B - 380V-400V 50 Hz 3 Ph |
NA |
✔ |
✔ |
|
|
Option C - 208 V 60 Hz 3 Ph |
NA |
✔ |
NA |
|
|
Option D - 460V-480V 60 Hz 3 Ph |
NA |
✔ |
✔ |
|
|
Option E - 110V-120V 60 Hz 1Ph |
✔ |
NA |
NA |
|
|
MCP Location Panel |
Option OR - Onboard Right Access |
✔ |
✔ |
✔ |
|
Option OL - Onboard Left Access |
✔ |
✔ |
✔ |
|
|
Option OF - Onboard Front Access |
✔ |
NA |
NA |
|
|
Option RM - Remote Mounted |
✔ |
✔ |
✔ |
|
|
Control Type |
PDI/ PB/ PDT/ PLC - Closed Loop Allen Bradley |
NA |
✔ |
✔ |
|
PDI/ PB/ PDT/ PLC - Closed Loop Siemens |
NA |
✔ |
✔ |
|
|
HMI/ PB/ PDT/ PLC - Closed Loop Allen Bradley |
NA |
✔ |
✔ |
|
|
HMI/ PB/ PDT/ PLC - Closed Loop Siemens |
NA |
✔ |
✔ |
|
|
Sentinel PDI/PDT - Open Loop |
✔ |
NA |
NA |
|
|
Cooling Type |
Option NIL - No Cooling |
NA |
✔ |
✔ |
|
Option CC - Chilled Water |
NA |
✔ |
✔ |
|
|
Option DX - Direct Expansion |
NA |
✔ |
✔ |
|
|
Option GL - Glycol |
NA |
✔ |
✔ |
|
Esco Pharma Downflow Booth (DFB) is designed in compliance with international cGMP guidelines. It is fully equipped to provide operator, process, and/or product protection during open handling processes such as: weighing / dispensing or charging of powder into intermediate bulk container (IBC), bins or equivalent, and sampling in cGMP warehouses.